Sonair Ultrasonic Mesh Nebulizer by MedPro
Regular price
$124.99
Sale
- Silent and Discreet Nebulization
- Compact + Portable
- One-Touch Operation
- Rechargeable
Nebulizer kit includes: 1 adult and 1 child mask, mouthpiece, USB cable, Accessory bag, Quick start and Instruction manual.
FAQ
Q: Is Sonair use contraindicated with any medications?
A: Yes - Sonair should not be used with Pentamidine - Patients with Pulmonary Edema,Acute Asthma, and Acute Pulmonary Infarction Episodes should not use Sonair.
Q: What is the maximum medication capacity?
A: 10 ml.
Q: Is there a minimum medication quantity requirement?
A: Yes, the minimum quantity should be at 0.5 ml in order for the medication to have contact with the mesh.
Q: Can Ventolin (salbutamol) be used for nebulization?
A: Yes - Ventolin (salbutamol) has been tested and is ok to use.
Q: Can Sonair be used with Pulmicort?
A: Yes - Pulmicort was tested and can be used with Sonair.
CLEANING-READ USER GUIDE FOR COMPLETE INSTRUCTIONS
Remove the mask or the mouthpiece from the nebulizer. |
Discard any residual medication by nebulzing water (below 40°C) for 1-2 minutes. |
Press on the button on the back of the nebulizer and pull up the medication cup. |
Wash the nebulizer nozzle, medication cup, and all accessories using warm soapy water (below 40°C). Wipe the machine and the accessories with clean medical gauze after cleaning. |
Q: Can Sonair be cleaned with vinegar and water?
A: Please refer to the CLEANING AND DISINFECTING Section in the User Guide.
It is recommended to use warm soapy water (below 40°C).
- Vinegar may be used to clean the medicine cup and accessories.
Q: Can the medication cup be placed in a dishwasher?
A: No - Using a dishwasher can be corrosive to the nebulizing headand may damage the accessories.
Q: Are there replacement parts for Sonair?
A: Yes - There are adult and child mask replacements, along with the medicine cups.
Q: Are the contraindications listed above unique to Sonair? (Patients with Pulmonary Edema, Acute Asthma, and Acute Pulmonary Infarction Episodes should not use Sonair.)
A:This information is NOT product specific.This contraindication would apply to the category of all nebulizers (not only mesh) for the following reasons:
1. Atomization inhalation may lead to increased dyspnea
2. Respiratory secretions, may lead to increased secretions and obstruction of the respiratory tract, thus aggravating the condition
Note: Nonobservance to cleaning instructions may impact performance and cause damage to the nebulizer. Any abuse, misuse, or accidental damage voids the warranty.